Generator Wattage Planner

List the appliances you want to power during an outage — quantity, running watts and additional starting watts from each nameplate — and mark which are essential and which run at the same time. The planner totals running load, shows two starting scenarios (the largest single motor start, and every motor starting together), adds a planning allowance you control, and compares the full list with essentials only. It is a planning worksheet, not an electrician-approved installation size.

Room mid-renovation with paint rollers, flooring planks and roofing shingles

How many watts of generator do I need?

Add the running watts of everything that runs at once, then add the single largest additional starting watts, assuming motors start one at a time. A refrigerator at 700 W running / 1,500 W additional, four 60 W lights and a 1,200 W microwave run at 700 + 240 + 1,200 = 2,140 W; the peak is 2,140 + 1,500 = 3,640 W. Additional starting watts are on top of running watts — total starting for the fridge alone is 2,200 W.

Key takeaways

  • Additional starting watts = total starting watts − running watts. Don't add both totals.
  • Usually only one motor starts at a time; the 'all together' scenario is a worst case.
  • Generator ratings can differ by fuel; check the manufacturer's spec sheet.
  • Never run a portable generator indoors or in a garage — carbon monoxide kills.

Enter your details

Setup

Optional margin you choose; no universal figure applies. It is shown separately so you can see its effect.

Appliance 1

Example value — replace with the nameplate or manual figure.

Extra watts above running during a motor start — not the total starting figure.

Appliance 2

Example value — replace with the nameplate or manual figure.

Extra watts above running during a motor start — not the total starting figure.

Appliance 3

Example value — replace with the nameplate or manual figure.

Extra watts above running during a motor start — not the total starting figure.

Estimated result

Peak with largest single start (all simultaneous loads)

3,640 W

Running 2,140 W + largest start 1,500 W

Essentials only, peak
2,440 W
With 0% allowance
3,640 W

All simultaneous loads

Running load
2,140 W
Largest additional start
1,500 W
Scenario 1: one motor starts at a time
3,640 W
Scenario 2: all motors start together
3,640 W
Scenario 1 + 0% allowance
3,640 W

Essential loads only

Running load
940 W
One motor starts at a time
2,440 W
All motors start together
2,440 W
With 0% allowance
2,440 W
  • Compare running load with the generator's rated (continuous) watts and the peak with its surge/starting watts, using the manufacturer's figures for the fuel you will use.
  • Motor starting draw varies; soft starters and load-management devices change it. Voltage (120 V vs 240 V legs) and transfer equipment are not modelled — have a licensed electrician size and install any connection to home wiring.

Appliance list

ApplianceQtyRunning WAdd. start WTotal start W (each)EssentialSimultaneous
Appliance 117001,5002,200YesYes
Appliance 2460060YesYes
Appliance 311,20001,200NoYes

Your result is an estimate based on the information entered.

Calculated in your browser

This calculator runs locally; your exact figures are not sent to our servers. Anonymous usage events (calculator name, field names, rounded value ranges) are recorded by Google Analytics — see the privacy policy.

How to use this calculator

  1. Choose how many appliances to list.
  2. Enter quantity, running watts and additional starting watts from each nameplate or manual.
  3. Mark essentials and anything that won't run at the same time.
  4. Set an optional allowance, then print the appliance list for your electrician.

What each input means

InputWhat it means
Running wattsContinuous draw from the nameplate or manual (or volts × amps for resistive loads).
Additional starting wattsExtra surge above running watts for motor loads such as compressors and pumps.
EssentialLoads you would keep during an outage if capacity is limited.
SimultaneousWhether the load runs at the same time as the others in your plan.

Formula used

Running = Σ (Qty × Running W) for simultaneous loads

Peak (one start) = Running + max(Additional start W)

Peak (all start) = Running + Σ (Qty × Additional start W)

Planned = Peak (one start) × (1 + Allowance ÷ 100)

Worked example

Example rows: fridge 1 × 700 W (+1,500), lights 4 × 60 W, microwave 1 × 1,200 W (non-essential). Running = 2,140 W; peak one start = 3,640 W; all start = 3,640 W (only one motor). Essentials only: running 940 W, peak 2,440 W. With a 10% allowance the essentials plan is 2,684 W.

Common mistakes to avoid

  • Adding total starting watts for every appliance

    This counts running watts twice and assumes everything starts at once.

  • Using example figures

    The pre-filled rows are examples only; nameplates vary widely.

  • Backfeeding through an outlet

    Connecting a generator to home wiring without a transfer switch can electrocute utility workers. Use a licensed electrician.

When the estimate may differ from reality

Real starting surges vary with motor condition and temperature, and a generator's usable output can be lower than its rating on some fuels, at altitude or with unbalanced 120 V legs.

Assumptions and limitations

What this calculator assumes

  • Watts entered are accurate nameplate or manufacturer figures.
  • Non-simultaneous loads are excluded from all totals.

What it does not account for

  • Does not size transfer switches, wiring or fuel supply and is not an electrician-approved installation size.
  • Actual motor inrush, voltage balance between 120 V legs, altitude and fuel type can change usable output.

Frequently asked questions

Are the starting watts in the presets real?
They are labelled examples to show how the worksheet works. Replace them with your appliance's nameplate or manufacturer data.

Sources and references